Retrofit
Dual-mode aerator nozzles on all 30 washroom and utility faucets take flow from 4.0 L/min to 1.5 L/min. Efficient use becomes the default, not something students must remember.
Student-led engineering, data and outreach for UN SDG 6. We set out to cut our school’s water use by 25% and cut it by 33.6%.
Our problem statement
How can we reduce water consumption and wastage in our school by 25%, creating a blueprint that benefits both our campus and the wider community?
The results
Monthly readings after the interventions, compared with where the school started.
0 litres saved every month
0 kWh saved every month
Source: pump current from our CT clamp and washroom footfall from a LiDAR sensor, logged to the RegenAqua dashboard where we tracked and calculated these results.
Inside the data
Two sensors watch the system around the clock. Their readings flow to our dashboard, where we track every day and calculate the results.
Clips around the pump cable and senses its current, so we know exactly when the pump runs and how much electricity it uses. No rewiring.
Counts people walking into the washroom, without cameras or photos, so we can compare water used with how many people used it.
Combines both streams into daily water use, pump runtime, energy and water per washroom visit, and tracks them against our 25% target.
Drag the slider through the day, or press play.
Modelled An average day rebuilt from our monthly totals (2,32,000 → 1,54,000 L and 276.8 → 166.1 kWh), assuming a 5,000 L tank and a 1.5 kW pump, with pump run times matched to the measured electricity. It will be replaced with day-by-day dashboard readings.
Slide to see the total if we keep saving at this month’s rate.
Projected Uses this month’s measured savings: 78,000 L, 110.7 kWh and 77.5 kg CO₂ per month.
From fixture to campus
Hardware, data and student behaviour work together as one campus system, instead of relying on awareness alone. Scroll through the four steps.
Standard outlet
A CT clamp senses the pump's current without cutting a wire.
Illustrative dayEvery litre wasted at a tap was pumped, stored and carried there first.
Litres per month. The orange dashed line marks our 25% target.
Dual-mode aerator nozzles on all 30 washroom and utility faucets take flow from 4.0 L/min to 1.5 L/min. Efficient use becomes the default, not something students must remember.
A current-transformer clamp watches the main water pump and a LiDAR sensor counts people walking into the washroom. Both feed our dashboard, so a pump running when no one needs water stands out as a possible leak.
Workshops connect the global water crisis and Bengaluru's aquifers to the taps students use every day, so they understand where their water comes from and what their choices change. Our outreach has reached 1,000+ people so far.
Meter readings and pump logs show the result: monthly use fell from 2,32,000 to 1,54,000 litres. That is a 33.6% cut against our 25% target, saving 110.7 kWh of pump electricity and 77.5 kg of CO₂ every month.
Three connected interventions turn water conservation from an abstract idea into a measurable campus system.
About RegenAqua
RegenAqua is a youth-driven environmental engineering project in Bengaluru. We *retrofit the taps students use every day, *measure what the campus really consumes, and *educate every class so the savings last.
Schools are both infrastructure systems and communities. A single intervention can change physical water use while teaching hundreds of students how resource systems work.
Hardware retrofits, sensor data and outreach on campus and beyond work together as one intervention, measured end to end.
Learn by doing
Four water games in one arcade. Step inside, pick a game, and come back to the site whenever you like.
completed the RegenAqua water conservation challenge
8/10 Every drop countsWhere the drop goes next
After the drain, a drop isn't lost. It takes one of three roads back, and every one ends with it being used again. The orange tags show where our project steps in.
Start a conversation
Get inInterested in deploying low-flow nozzle retrofits or IoT pump telemetry at your institution? Write to the team directly.
The end of one drop's journey
Fill the pipe to rewind
A once-lively lake is running dry and pollution is closing in. Catch clean water to bring it back, and keep sewage and chemical waste out of your basin.
Arrow keys or A / D to move · drag or tap on mobile · P to pause
The lake will wait for you.
You couldn't save the lake.
Five nights watching the school's pipes from the control room. Survive until 6 AM.
At night nobody uses water, so any flow is a leak. Watch the cameras, fix leaks before they burst, and don't run out of power. Make it to 6 AM.
Keys 1, 2, 3 switch cameras · click or tap leaks · P pauses
The leaks will wait.
Each camera has a flow meter. At night it should read zero, so a rising meter means a leak in that zone, even when you're not watching it. Valves shut a wing's leaks off, but their motors drain power.
Six cases. Read the sensor data, mark when the problem happened, and name the cause.
LiDAR counts people walking into the washroom each hour.
Litres per minute flowing to the washroom taps and cisterns.
The CT clamp shows when the pump is running.
Normal days follow the people: more visitors, more water, then the pump refills the tank. Your job is to spot the moments where the data doesn't add up.
These are practice cases with simulated data.
What caused it?
Run a campus's water for a whole term. Spend wisely, handle surprises, and hit the target.